FRONIUS SYMO ADVANCED 10.0-3-M WLAN
6981.02
Shipping within | 48 hours |
Shipping price | The Lack Of |
The Availability Of | 2 opak |
Order by phone: +48 720829292
INPUT ATA
Number of MPP trackers: 2
Max. input current (Idc max): 27.0 / 16.5 A
Max. short-circuit current of the module field*: 55.7 / 34.0 A
DC input voltage range (Udc min – Udc max): 200 - 1000 V
Starting voltage (Udc start): 200 V
Rated input voltage (Udc,r): 600 V
MPP voltage range (Umpp min – Umpp max): 270 - 800 V
Usable MPP voltage range: 200 - 800 V
Number of DC connections: 3 + 3
Max. photovoltaic generator power (Pdc max): 15 kWpeak
OUTPUT DATA
AC rated power (Pac,r): 10 kW
Max. output power (Pac max): 10 kVA
AC output current (Iac nom): 14.4 A
Mains connection (Uac,r): 3~ NPE 400/230, 3~ NPE 380/220 V
AC voltage range (Umin - Umax): 150 - 280 V
Frequency (fr): 50 / 60 Hz
Frequency range (fmin - fmax): 45 - 65 Hz
Non-linear distortion factor: <3% @Pnom (230/400VAC 50Hz)
Power factor (cos φac,r): 0 - 1 ind,/cap,
GENERAL INFORMATION
Dimensions / width: 510 mm
Dimensions (height): 725 mm
Dimensions (depth): 225 mm
Weight: 32.1 kg
Weight with packaging: 38.5 kg
Degree of protection: IP 66
Protection class: 1
Overvoltage category (DC/AC) 1): 2 / 3
Energy consumption at night: < 1 W
Cooling: Adjustable ventilation
Installation: Installation inside and outside buildings
Ambient temperature range: -25°C - +60°C
Permissible air humidity: 0 - 100%
Max. altitude 2): 2,000 m / 3,400 m
DC connection technology: 6x DC+ and 6x DC- screw terminals 2.5–16 mm²
AC connection technology: 5-pin AC screw terminals 2.5–16 mm²
Certificates held and standards met: IEC 62109-1/-2, IEC 62116, IEC 61727, VDE 0126-1-1/A1, VDE AR-N 4105, G98/1, G99/1, AS/NZS 4777.2, UNE 206007 -1, CEI 0-21, CEI 0-16, NRS 097-2-1, TOR Erzeuger Type A, EN 50549-1/-2, IEC 61683, IEC60068
EFFICIENCY COEFFICIENT
Max. efficiency factor (photovoltaic installation - power grid): 97.8%
European efficiency ratio (ηEU): 95.5 / 97.1 / 96.3%
η at 5% Pac,r 3): 89.0 / 91.5 / 87.1%
η at 10% Pac,r 3): 92.6 / 94.8 / 92.6%
η at 20% Pac,r 3): 94.8 / 96.7 / 95.5%
η at 25% Pac,r 3): 95.3 / 97.0 / 96.1%
η at 30% Pac,r 3): 95.7 / 97.3 / 96.5%
η at 50% Pac,r 3): 96.2 / 97.6 / 97.1%
η at 75% Pac,r 3): 96.2 / 97.8 / 97.4%
η at 100% Pac,r 3): 96.2 / 97.8 / 97.5%
MPP adaptation efficiency rate: >99.9%
SECURITY
DC insulation measurement: Yes
Behavior in the event of overload: Operating point shift, power limiter
DC disconnect: Yes
DC Reverse polarity protection: Yes
Arc detection - AFCI (Fronius Arc Guard): Yes
CONNECTORS
WLAN / Ethernet LAN: Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs: Connection to remote control receiver, power management
USB (socket type A) 4): Datalogging, updating of inverters via USB media
2x RS422 (RJ45 socket) 4): Fronius Solar Net
Signaling output 4): Energy management (potential-free relay output)
Datalogger and web server: Integrated
External input 4): S0 counter connection / surge protection monitoring
RS485: Modbus RTU SunSpec or energy meter connection